Detection solutions
tailored to your market's needs.

Learn more about the Fixed Gas and Flame Detection markets we serve >>

Fixed Gas & Flame Detection

MSA Chillgard VRF Refrigerant Leak Detector Unit - Front View

Chillgard® VRF Refrigerant Leak Detector

MSA Chillgard VRF Refrigerant Leak Detector is the first industry detector for Variable Refrigerant Flow Systems (VRF) with integrated BACnet capability. Therefore, it can be directly connected with any Building Management Systems (BMS). MSA applies its proven Photoacoustic infrared sensing technology that provides a stable zero baseline, minimizes cross-sensitivities and offers low cost of ownership through minimum maintenance required.
SB100 Ultrasonic Bump Tester

SB100 Ultrasonic Bump Tester

The SB100 is a hand-held battery-operated rechargeable ultrasonic tester designed to bump test General Monitors ultrasonic gas leak detectors. The SB100 is useful for quick tests where physical access to the ultrasonic gas detector can be difficult. The unit can be used to bump test up to 18 meters away from the detector in Class 1, Div 1&2 hazardous areas.
Series 47K

Series 47K

Designed to detect flammable gas or vapor, the stainless steel Series 47K gas sensors offer a cost-effective way to detect hazards in the air. The sensors come in poison resistant and high-temperature versions, and have three- or five-wire connection.
MSA Ultima Series XE Gas Detector

Ultima® X Series Gas Monitors

Designed to provide thorough, continuous monitoring of many hazardous gases, the indoor/outdoor Ultima X Series Gas Monitors offer excellent performance and MSA quality craftsmanship. DuraSource™ Technology offers extended sensor life, while HART provides convenient setup, calibration and diagnostics. HART also allows for existing component install and wiring to be used. A single circuit board increases reliability, while our patented sensor disconnect-underpower feature allows all sensors to be replaced in hazardous areas without area declassification. The units are crafted from either stainless steel or polycarbonate, and the interchangeable smart sensors eliminate the need for reconfiguration. Our scrolling LCD screen display sensor reading and gas type, while the calibration process includes date stamping and the ability to calibrate locally or remotely.
FlameGard® 5 MSIR Flame Detector

FlameGard® 5 MSIR Flame Detector

MSA's FlameGard® 5 MSIR Detector is an advanced multi-spectrum flame detector designed to provide superior false alarm immunity with the widest field of view. The detector employs a state-of-the-art multi-spectrum infrared (MSIR) sensor array with a sophisticated Neural Network Technology (NNT) system.
S4000CH Combustible Gas Detector

S4000CH Combustible Gas Detector

The S4000CH Intelligent Sensor is a microprocessor-based transmitter designed for use with General Monitors industry-leading catalytic bead sensors. It features one person calibration and virtually self-calibrates by simply activating a magnetic switch and applying gas. It monitors combustible gases and vapors within the lower explosive limit (LEL) and provides status indication and alarm outputs. Complies with ANSI/ISA 12.13.01-2000 performance requirements for combustible gas detectors.
Ultima® Calibrator

Ultima® Calibrator

The Ultima Calibrator offers the industry's simplest, quickest calibration. Simple, three-button device is purpose-built for calibrating and changing the address of Ultima and Ultima X Gas Monitors and the Toxgard II Gas Monitor.
FlameGard® 5 UV/IR Flame Detector

FlameGard® 5 UV/IR Flame Detector

The precision-crafted FlameGard® 5 UV/IR Flame Detector monitors both ultraviolet and infrared (UV & IR) spectral ranges, which makes it highly immune to false alarms caused by lightning, arc welding, hot objects and other sources of radiation. The unit's Continuous Optical Path Monitoring (COPM) checks both the optical path integrity and the detector's electronic circuitry once a minute, while the wide field of view enables greater fire detection coverage.
SM5000 Sampling Module

SM5000 Sampling Module

Built for safety programs that demand gas concentration measurement before allowing entrance to an area, the SM5000 Sampling Module is exclusively designed to work with the Ultima X5000, Ultima XE and General Monitors S5000 gas monitors. The unit features an explosion-proof design and reliably extracts a sample from any confined or inaccessible area—or any area that is too hot, cold, or otherwise harsh—and delivers gas concentration reading directly to the installed gas monitor.
MSA FL3100H UV/Infared Flame Detector

FL3100H UV/IR Flame Detector

The FL3100H is an Ultraviolet / Infrared flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It monitors in both the ultraviolet (UV) and infrared (IR) spectral ranges, making it highly immune to false alarms. Configurations with dual Modbus and HART are available. Modbus and HART data can be used for predictive maintenance. The flame detector's electronics are integral within its explosion-proof housing, allowing detector information to be processed locally.
Ultima® XIR Gas Monitor

Ultima® XIR Gas Monitor

The microprocessor-based, infrared Ultima XIR gas detector is precisely engineered to continuously monitor for combustible gases and vapors. The unit features DuraSource Technology, which offers improved IR life, and a HART port for easy output access. The explosion-proof stainless steel monitor works indoors or outdoors and features infrared technology that eliminates the need for frequent calibrations. Its operations are based on dual-wavelength, heated-optics technology, which compensates for temperature, humidity and aging effects. The unit uses only one circuit board for increased reliability, and the sensor life isn't reduced by exposure to gas. The LCD screen provides scrolling information, while optional quick-check LEDs provide increased visibility.